     Aim I-prober 520 positional current probe

    I-prober 520 - PCB track Touch & Measure

     

      Current measurement from insulated probing of conductor
      Suitable for observation and measurement of current in
        PCB tracks, component leads and ground planes
      Wide dynamic range of 10mA to 20A peak to peak
      Wide bandwidth of DC to 5MHz
      Low noise figure equivalent to <6mA rms at full B/W
      Safety rated to 300V Cat II (600V Cat 1)
      Suitable for connection to any oscilloscope
      High accuracy general purpose H-field probe
      Converts to ?closed magnetic circuit? current probe

     

    More Information: Data Sheet

     

     

     
     

    TEChnical Specifications

    General Specifications (All Modes)

    Output Signal
    Maximum Output: ? 10V .
    Oscilloscope Input: Suitable for an input impedance of 1MOhms in parallel with < 30pF.
    Trace Position: Wide range DC offset control within control box.
    Safety
    Max. Circuit Voltage: 300V Cat II (on AC line circuits). 600V Cat 1 (on uncategorised secondary circuits inside equipment).
    Max. Tip Temperature: 150oC maximum allowable temperature at probe tip.
    Conformance: Complies with EN61010-1 & EN61010-031
    Bandwidth Control
    Switch Position:           Full                500kHz                2Hz
    Nominal Bandwidth: DC to 5MHz     DC to 500kHz      DC to 2Hz
    Risetime:                    <70ns             700ns                 175ms
    Aberrations:                <+/-5%             <+/-1%                  <+/-1%
    Noise (Typical)*:        6mA rms        3mA rms           1.5mA rms
    * This is the noise level for current measurement using the Toroid attachment. For PCB track measurement the equivalent noise will depend upon the track width and gain setting but will be similar to the Toroid measurement figure for a track width of 0.5mm.
    HF Performance (bandwidth switch at Full)
    Propagation Delay: 60ns typical (to 10%).
    Bandwidth: DC to 5MHz (small signal)
    Slew Rate: 15A/us (equivalent).
    Overload Indication
    Indicator Threshold: Indicator LED within control box will light if output voltage exceeds +/- 10V or if large magnetic fields cause the system to saturate.
    Power Source
    Power Supply: 5.2V at up to 5 watts from AC line adaptor (supplied).
    Mechanical
    Probe Dimensions: 155mm x 38mm x 28mm max; 2.8mm x 1.8mm at tip
    Cable Length: 2m from probe tip to output BNC
    EMC
    Conformance: Complies with EN61326

    Magnetic Field Measurement (Mode = Field)

    Scaling Factor: 250uT (or 200A/m) per Volt.
    Accuracy and Linearity: +/-3%
    Maximum Field: +/-2.5mT (2000A/m).

    Current Measurement using Toroid (Mode = Wire)

    Scaling Factor: 1 Amp per Volt.
    Accuracy and Linearity: +/-5%
    Current Range: +/-10mA to +/-10A (DC + peak)
    Max. Wire Diameter: 3.5mm (unbroken) or 6mm (end fed)

    Current Measurement in PCB Tracks (Mode = PCB Track)

    Scaling Factor: Adjustable to 1 Amp per Volt for track widths 0.2mm to 3.5mm (0.007" to 0.14") and 2 Amp per volt for track widths 3mm to 6.5mm (0.125" to 0.25") using Calibrator and compensation grapH.
    Sensor Spacing: 0.7mm distance from sensor to PCB track set by probe design.
    Calibrator: Built-in calibrator within the control box providing an AC or DC calibration current through a 0.5mm track.